Sample Project — DN500 Metal Bellows Expansion Joint
Compare EJMA 10th Edition, EN 14917, ASME VIII Division 1 Mandatory Appendix 26, and AD 2000 B13 results on a single dashboard.
Fatigue Life Comparison by Standard
Allowable cycles and design target
Quick Results
Current load cycle
Critical Warnings
Scope and input checks
Stress Components
Automatic result for unreinforced U-shaped bellows
Project and Design Inputs
Highlighted fields feed directly into the calculation engine. Material selection updates E at the design temperature.
Project Identification
Report title and traceability information
Expansion Joint Configuration
Defines the scope of the automatic stress calculation
Bellows Geometry
SI units: mm
Pressure and Material
Verify preliminary material values against the material certificate or applicable code tables
Standard Correction Factors
Change defaults only with a documented engineering justification
Manual Total Stress Inputs
Used for reinforced or toroidal geometries and validated external analyses. 0 = automatic.
Design Laboratory
Sweep the number of convolutions and ply thickness to compare lower-spring-rate alternatives that meet the fatigue-life target.
Sweep Range
Candidate geometries derived from the current project
Recommended Alternative
Balances low spring rate and compact flexible length among acceptable candidates
Candidate Geometry Table
First 60 results; acceptable candidates are listed first
| Rank | N | t | Lb | Δq | Governing life | Miner D | Kb | Check | |
|---|---|---|---|---|---|---|---|---|---|
| The sweep has not been run. | |||||||||
Sensitivity Curve
Effect of the selected parameter on governing life
Current Design / Recommendation
Key engineering differences
Movement and Critical-Fiber Analysis
Axial, lateral, and angular movements are converted to equivalent movement per convolution using two endpoint positions.
Cycle Endpoint Positions
Enter signs according to the actual installation coordinate system
Position 1
Position 2
Critical-Fiber Movement Envelope
Full range between the positive and negative critical fibers
Position Calculation Table
The two critical fibers are evaluated separately at each position
| Position | Δqx | Selected Δqy | Δqθ | Fiber + | Fiber − | EN Fiber + | EN Fiber − |
|---|
Multi-Level Load Spectrum
Define start-up, shutdown, and operating cycles in separate rows. The total usage factor D must be ≤ 1.
| Active | Load case | ni | Pmax MPa | Δq mm/convolution | EN St manual | ASME St manual | EJMA St manual | AD 2ε % manuel | EN Ui | ASME Ui | EJMA Ui | AD Ui |
|---|
Cumulative Damage Overview
The 1.0 line is the acceptance limit
Standard Results and Formula Traceability
Each result is presented with its scope of applicability, stress components, and fatigue curve.
Geometry and Applicability Checks
Code scope conditions are evaluated together with the supplied AD 2000 preliminary-geometry formulas.
Code Scope Checks
Critical failures affect the governing result
Preliminary Geometry Envelope
Guidance values derived from the source Excel formulas
Engineering Calculation Report
Use your browser’s PDF printer to generate a professional report.
References and Application Limits
This application is an engineering aid that combines the supplied standards and calculation workbook.
Important engineering notice
Results depend on the accuracy of the entered geometry and material properties. This application does not replace verification of manufacturing tolerances, weld details, corrosion, vibration, flow-induced effects, hardware, anchors, guides, pressure-thrust restraint, NDT, or PED conformity assessment. The final design must be reviewed by a qualified metal bellows expansion joint engineer.