Fabric Expansion Joint & Industrial Ducting Engineering Glossary
Compiled by the BundleTec engineering office under Nayri Akbuğa, this reference glossary standardizes terminology used across global power, cement, FGD, and petrochemical specifications.
#1 · Fabric Expansion Joint
Non-metallic multi-layer flexible connector absorbing thermal growth and vibration in gas ducts (-40°C to +1000°C).
#2 · Breech Opening (L_inst)
Installed face-to-face distance between mating duct steel flanges holding the flexible belt.
#3 · Developed Belt Width (W_dev)
Total unrolled textile width including installed gap, axial/lateral geometry, 12% slack, and flange clamps.
#4 · Axial Compression (−ΔX)
Inward closing movement of duct flanges caused by thermal expansion of adjacent steel runs.
#5 · Axial Extension (+ΔX)
Outward opening movement during cold shutdown or structural settlement.
#6 · Lateral Deflection (±ΔY)
Transverse shear offset perpendicular to the gas duct centerline absorbed by flexible belt convolutions.
#7 · Angular Rotation (θ)
Bending tilt angle between upstream and downstream duct flanges during asymmetric heating.
#8 · Concurrent Multi-Axial Movement
Simultaneous axial, lateral, and angular displacements absorbed inside one compact fabric gap.
#9 · Bulging Slack (10–12%)
FSA-DSJ circumferential excess belt length preventing tensile overload under concurrent extension and shear.
#10 · Anchor Reaction Force
Thrust and spring load transferred to duct supports; Fabric belt spring stiffness is negligible (~10–50 N/m perimeter vs metal bellows); structural duct anchors still react internal pressure thrust (P × A).
Technical Guide →#11 · RAL-GZ 719
Official German Quality Assurance specification (March 2017) for Single-Layer and Multi-Layer fabric expansion joints.
Technical Guide →#12 · EN 1593 Nekal® Bubble Test
Official RAL-GZ 719 gas-tightness verification using foaming agent at minimum 50 hPa differential pressure.
Technical Guide →#13 · DIN 53508 Thermal Aging
Accelerated elastomer aging test verifying coating retention under continuous heat exposure.
#14 · ISO 132 De Mattia Flex Test
Repeated cyclic bending test evaluating crack resistance of coated elastomeric membranes.
#15 · DIN EN ISO 13934-1
Strip tensile breaking force test requiring ≥4,000 N/50 mm for heavy industrial fabric carcasses.
#16 · Helium Mass-Spectrometer QA
BundleTec extended factory tightness protocol achieving Q ≤ 1.0×10⁻³ mbar·l/(s·m) on critical ducts.
#17 · FSA-DSJ-401
Fluid Sealing Association specification for terpolymer fluoroelastomer belts in flue gas ducting.
Technical Guide →#18 · FSA Clamping Bar Radius
Minimum R ≥ 3 mm rounded edge on clamping bars and flanges to prevent belt cutting.
#19 · Three-Pass Cross-Star Torque
Sequential bolt tightening (30% → 60% → 100%) ensuring uniform gasket compression without leaks.
#20 · 24-Hour Hot Retorque
Mandatory post-commissioning bolt torque check compensating for initial thermal gasket relaxation.
#21 · Pure Sintered PTFE Film
Zero-porosity cross-laminated fluoropolymer barrier offering universal pH 0–14 resistance up to +260°C.
Technical Guide →#22 · FKM / Viton Fluoroelastomer
Acid- and oil-resistant fluorinated elastomer rated to +200°C continuous in flue gas environments.
Technical Guide →#23 · Silicone-Coated E-Glass
High-flexibility weather-resistant composite membrane operating from -35°C to +240°C.
Technical Guide →#24 · EPDM Elastomer
Ozone-, steam-, and moisture-resistant elastomer suited for fan air and ventilation ducts up to +130°C.
Technical Guide →#25 · CMS-Bio Soluble Fiber
1200°C Calcium-Magnesium-Silicate bio-soluble ceramic insulation blanket replacing regulated RCF fibers.
Technical Guide →#26 · High-Silica Textile
96%+ SiO₂ woven fabric retaining mechanical integrity up to +1000°C continuous gas exposure.
#27 · Inconel 625 Wire Mesh
Nickel-chromium-molybdenum wire reinforcement resisting gas turbine thermal shock and oxidation.
Technical Guide →#28 · AISI 310S (1.4845)
High-temperature austenitic stainless steel used for hot frames, liners, and wire meshes up to +900°C.
#29 · Hardox 400 / 500 Liner (≤250°C)
Abrasion-resistant wear steel protecting internal particle deflectors against cement clinker and fly ash.
#30 · Hastelloy C-276
Nickel-molybdenum-chromium superalloy resisting wet sulfuric and hydrochloric condensate corrosion.
#31 · Gas Barrier Membrane
Primary impermeable fluoropolymer or elastomer layer blocking flue gas and acid vapor leakage.
#32 · Bolster Insulation Pillow
Internal multi-layer ceramic/silica cushion dropping +1000°C gas heat below +260°C at the PTFE barrier.
#33 · ISO 13732-1 Outer Skin Limit
Ergonomic burn-protection benchmark targeting <60°C external belt temperature for plant personnel safety.
#34 · Acid Dew Point (T_dew)
Critical temperature (typically 130°C–150°C) where gaseous SO₃ condenses into corrosive liquid H₂SO₄.
Technical Guide →#35 · Verhoff-Banchero Equation
Empirical correlation computing sulfuric acid dew point in Kelvin from H₂O and SO₃ partial pressures (mmHg).
Technical Guide →#36 · FGD Wet Scrubber
Flue Gas Desulfurization absorber removing SO₂ using limestone slurry under corrosive wet conditions.
Technical Guide →#37 · ATEX 2014/34/EU
European directive governing equipment operating safely in explosive gas (Zone 1/2) and dust (Zone 21/22) zones.
Technical Guide →#38 · Conductive Antistatic PTFE
Carbon-filled PTFE barrier with surface resistivity Rs < 10⁶ Ω preventing electrostatic spark discharge.
#39 · Equipotential Bonding Jumper
Braided copper or AISI 316 grounding strap maintaining earth resistance below 1 Ω across flanges.
#40 · T-Class Surface Limit
ATEX maximum external temperature classification (e.g. T4 <135°C, T3 <200°C) preventing dust ignition.
#41 · U-Type Flanged Joint
Preformed belt with integral 90° fabric flanges clamped directly between mating duct flanges up to +350°C.
Technical Guide →#42 · Flat Belt Standoff Frame
Elevated steel frame moving clamping bolts away from radiant gas heat for +300°C to +1000°C service.
Technical Guide →#43 · Cavity Pillow Joint
Internally insulated recessed cavity architecture offering >28 dB acoustic attenuation and ash resistance.
#44 · Hot-to-Hot Framing
Standoff frame connecting two uninsulated or externally insulated high-temperature steel ducts.
#45 · Hot-to-Cold Framing
Asymmetric transition frame joining an uninsulated hot duct to an internally insulated cold casing.
#46 · Cold-to-Cold Framing
Dual internally insulated duct framing keeping both clamping flange interfaces below +60°C.
#47 · Particle Deflector (PD)
Telescopic upstream steel flow liner shielding the fabric cavity from abrasive gas streams up to 45 m/s.
#48 · Condensate Drain (DP & DB)
Bottom gutter and corrosion-resistant drain nozzle evacuating liquid acid pools from wet ducts.
#49 · Single-Axis Particle Barrier (SAPB)
Internal flexible barrier preventing fly ash packing during predominantly axial duct movements.
#50 · Double-Axis Particle Barrier (DAPB)
Floating multi-directional barrier preventing dust compaction during ±150 mm concurrent movements.
#51 · Particle Discharge Pipe (PEB)
Gravity bottom-purging chute discharging accumulated dust from horizontal cement and ESP ducts.
#52 · Flange Heat Dissipation Fins (FK)
Welded carbon steel or AISI 304/310S standoff cooling fins (mechanically clamped Cu/Al ≤250°C) reducing flange clamping temperatures by 100°C–180°C.
#53 · Tadpole Flange Gasket (TG)
Bulb-and-tail refractory sealing gasket providing thermal break and gas tightness under clamping bars.
#54 · Shipping Bars / Transit Brackets
Temporary steel spacers holding design face-to-face length during transport; must be removed before startup.
#55 · Flow Direction Arrow
Permanent directional stamp ensuring internal liners are welded upstream and telescope downstream.
#56 · Fabric Flutter
Aerodynamic membrane oscillation in turbulent high-velocity fan ducts prevented by flow sleeves.
#57 · Vacuum Anti-Collapse Ring
Domed internal stiffening ring preventing inward belt necking under severe negative suction pressure.
#58 · HRSG Inlet Diffuser
Heat Recovery Steam Generator transition zone facing 0°C→+650°C fast-start gas turbine thermal shock.
Technical Guide →#59 · Peaking Gas Turbine Shock
Rapid startup temperature ramp causing severe thermal gradients across turbine exhaust compensators.
#60 · Air Preheater (APH)
Boiler regenerative heat exchanger requiring multi-layer FlueTec™ compensators on hot flue ducts.
#61 · DeNOx / SCR Duct
Selective Catalytic Reduction flue gas line operating around +320°C–+420°C with ammonia slip.
#62 · Electrostatic Precipitator (ESP)
High-dust particulate collector inlet/outlet duct protected by ArminTec™ and DAPB barriers.
#63 · Cyclone Preheater Riser
Cement kiln suspension preheater duct exposed to abrasive alkaline raw meal and clinker dust.
Technical Guide →#64 · EAF Canopy Hood
Electric Arc Furnace fume extraction duct enduring cyclic heat surges and metallic spark carryover.
Technical Guide →#65 · ID / FD / PA Fans
Induced Draft, Forced Draft, and Primary Air industrial blowers isolated by FanTec™ (95% vibration cut).
Technical Guide →#66 · FanTec™ Series
BundleTec fan vibration isolation fabric joint (-35°C to +250°C, ±15,000 Pa / ±150 mbar).
Technical Guide →#67 · ChemTec™ Series
BundleTec 100% pure sintered PTFE acid-proof fabric joint (-40°C to +260°C, ±35,000 Pa).
Technical Guide →#68 · ArminTec™ Series
BundleTec Hardox 400 (≤250°C) & AISI 310S (250–550°C) abrasion-armored fabric joint (-30°C to +550°C, ±15,000 Pa, up to 45 m/s).
Technical Guide →#69 · FlueTec™ Series
BundleTec CMS-Bio multi-layer boiler flue gas fabric joint (+100°C to +750°C, ±35,000 Pa).
Technical Guide →#70 · GtTec™ Series
BundleTec Inconel 625 gas turbine thermal-shock fabric joint (+400°C to +1000°C, ±15,000 Pa).
Technical Guide →#71 · FabricSim™ Solver
BundleTec multi-physics simulator for thermal gradients, acid dew point, kinematics, and 3D CAD.
Technical Guide →#72 · CyclePro™ Software
BundleTec metallic bellows fatigue and squirm analyzer per EJMA 10/11, EN 14917, and ASME VIII App. 26.
Technical Guide →#73 · RubberPro™ Software
BundleTec elastomeric expansion joint reliability simulator per DIN 4809, FSA, and 14-mode Weibull frailty.
Technical Guide →#74 · EJMA 10th / 11th Edition
Expansion Joint Manufacturers Association calculation standard for metallic bellows stress and cycle life.
Technical Guide →#75 · EN 14917:2009+A1:2012
European harmonized standard for metallic bellows expansion joints under PED 2014/68/EU.
Technical Guide →#76 · ASME VIII Div. 1 App. 26
Mandatory pressure vessel code governing U-shaped and toroidal metallic expansion joints.
Technical Guide →#77 · DIN 4809
German pressure-temperature derating and durability standard for elastomeric rubber expansion joints.
#78 · Linear Expansion Coefficient (α)
Material thermal growth rate per meter and degree Celsius (12×10⁻⁶ carbon steel; 16.5×10⁻⁶ AISI 304).
Technical Guide →#79 · 48-Hour Emergency Turnaround
BundleTec rapid fabrication line delivering custom fabric belts within 48 hours for unplanned outages.
Technical Guide →#80 · On-Site Belt Replacement
Replacing a worn multi-layer fabric belt on existing standoff frames without cutting steel ductwork.
Technical Guide →