ENGINEERING GLOSSARY // 80 DEFINED TERMS

Fabric Expansion Joint & Industrial Ducting Engineering Glossary

80 verified engineering definitions spanning multi-layer fabric compensators, RAL-GZ 719, FSA-DSJ, ATEX, acid dew point, and metallic/rubber codes.

Fabric Expansion Joint & Industrial Ducting Engineering Glossary

Compiled by the BundleTec engineering office under Nayri Akbuğa, this reference glossary standardizes terminology used across global power, cement, FGD, and petrochemical specifications.

80 terms shown

#1 · Fabric Expansion Joint

Non-metallic multi-layer flexible connector absorbing thermal growth and vibration in gas ducts (-40°C to +1000°C).

#2 · Breech Opening (L_inst)

Installed face-to-face distance between mating duct steel flanges holding the flexible belt.

#3 · Developed Belt Width (W_dev)

Total unrolled textile width including installed gap, axial/lateral geometry, 12% slack, and flange clamps.

#4 · Axial Compression (−ΔX)

Inward closing movement of duct flanges caused by thermal expansion of adjacent steel runs.

#5 · Axial Extension (+ΔX)

Outward opening movement during cold shutdown or structural settlement.

#6 · Lateral Deflection (±ΔY)

Transverse shear offset perpendicular to the gas duct centerline absorbed by flexible belt convolutions.

#7 · Angular Rotation (θ)

Bending tilt angle between upstream and downstream duct flanges during asymmetric heating.

#8 · Concurrent Multi-Axial Movement

Simultaneous axial, lateral, and angular displacements absorbed inside one compact fabric gap.

#9 · Bulging Slack (10–12%)

FSA-DSJ circumferential excess belt length preventing tensile overload under concurrent extension and shear.

#10 · Anchor Reaction Force

Thrust and spring load transferred to duct supports; Fabric belt spring stiffness is negligible (~10–50 N/m perimeter vs metal bellows); structural duct anchors still react internal pressure thrust (P × A).

Technical Guide →

#11 · RAL-GZ 719

Official German Quality Assurance specification (March 2017) for Single-Layer and Multi-Layer fabric expansion joints.

Technical Guide →

#12 · EN 1593 Nekal® Bubble Test

Official RAL-GZ 719 gas-tightness verification using foaming agent at minimum 50 hPa differential pressure.

Technical Guide →

#13 · DIN 53508 Thermal Aging

Accelerated elastomer aging test verifying coating retention under continuous heat exposure.

#14 · ISO 132 De Mattia Flex Test

Repeated cyclic bending test evaluating crack resistance of coated elastomeric membranes.

#15 · DIN EN ISO 13934-1

Strip tensile breaking force test requiring ≥4,000 N/50 mm for heavy industrial fabric carcasses.

#16 · Helium Mass-Spectrometer QA

BundleTec extended factory tightness protocol achieving Q ≤ 1.0×10⁻³ mbar·l/(s·m) on critical ducts.

#17 · FSA-DSJ-401

Fluid Sealing Association specification for terpolymer fluoroelastomer belts in flue gas ducting.

Technical Guide →

#18 · FSA Clamping Bar Radius

Minimum R ≥ 3 mm rounded edge on clamping bars and flanges to prevent belt cutting.

#19 · Three-Pass Cross-Star Torque

Sequential bolt tightening (30% → 60% → 100%) ensuring uniform gasket compression without leaks.

#20 · 24-Hour Hot Retorque

Mandatory post-commissioning bolt torque check compensating for initial thermal gasket relaxation.

#21 · Pure Sintered PTFE Film

Zero-porosity cross-laminated fluoropolymer barrier offering universal pH 0–14 resistance up to +260°C.

Technical Guide →

#22 · FKM / Viton Fluoroelastomer

Acid- and oil-resistant fluorinated elastomer rated to +200°C continuous in flue gas environments.

Technical Guide →

#23 · Silicone-Coated E-Glass

High-flexibility weather-resistant composite membrane operating from -35°C to +240°C.

Technical Guide →

#24 · EPDM Elastomer

Ozone-, steam-, and moisture-resistant elastomer suited for fan air and ventilation ducts up to +130°C.

Technical Guide →

#25 · CMS-Bio Soluble Fiber

1200°C Calcium-Magnesium-Silicate bio-soluble ceramic insulation blanket replacing regulated RCF fibers.

Technical Guide →

#26 · High-Silica Textile

96%+ SiO₂ woven fabric retaining mechanical integrity up to +1000°C continuous gas exposure.

#27 · Inconel 625 Wire Mesh

Nickel-chromium-molybdenum wire reinforcement resisting gas turbine thermal shock and oxidation.

Technical Guide →

#28 · AISI 310S (1.4845)

High-temperature austenitic stainless steel used for hot frames, liners, and wire meshes up to +900°C.

#29 · Hardox 400 / 500 Liner (≤250°C)

Abrasion-resistant wear steel protecting internal particle deflectors against cement clinker and fly ash.

#30 · Hastelloy C-276

Nickel-molybdenum-chromium superalloy resisting wet sulfuric and hydrochloric condensate corrosion.

#31 · Gas Barrier Membrane

Primary impermeable fluoropolymer or elastomer layer blocking flue gas and acid vapor leakage.

#32 · Bolster Insulation Pillow

Internal multi-layer ceramic/silica cushion dropping +1000°C gas heat below +260°C at the PTFE barrier.

#33 · ISO 13732-1 Outer Skin Limit

Ergonomic burn-protection benchmark targeting <60°C external belt temperature for plant personnel safety.

#34 · Acid Dew Point (T_dew)

Critical temperature (typically 130°C–150°C) where gaseous SO₃ condenses into corrosive liquid H₂SO₄.

Technical Guide →

#35 · Verhoff-Banchero Equation

Empirical correlation computing sulfuric acid dew point in Kelvin from H₂O and SO₃ partial pressures (mmHg).

Technical Guide →

#36 · FGD Wet Scrubber

Flue Gas Desulfurization absorber removing SO₂ using limestone slurry under corrosive wet conditions.

Technical Guide →

#37 · ATEX 2014/34/EU

European directive governing equipment operating safely in explosive gas (Zone 1/2) and dust (Zone 21/22) zones.

Technical Guide →

#38 · Conductive Antistatic PTFE

Carbon-filled PTFE barrier with surface resistivity Rs < 10⁶ Ω preventing electrostatic spark discharge.

#39 · Equipotential Bonding Jumper

Braided copper or AISI 316 grounding strap maintaining earth resistance below 1 Ω across flanges.

#40 · T-Class Surface Limit

ATEX maximum external temperature classification (e.g. T4 <135°C, T3 <200°C) preventing dust ignition.

#41 · U-Type Flanged Joint

Preformed belt with integral 90° fabric flanges clamped directly between mating duct flanges up to +350°C.

Technical Guide →

#42 · Flat Belt Standoff Frame

Elevated steel frame moving clamping bolts away from radiant gas heat for +300°C to +1000°C service.

Technical Guide →

#43 · Cavity Pillow Joint

Internally insulated recessed cavity architecture offering >28 dB acoustic attenuation and ash resistance.

#44 · Hot-to-Hot Framing

Standoff frame connecting two uninsulated or externally insulated high-temperature steel ducts.

#45 · Hot-to-Cold Framing

Asymmetric transition frame joining an uninsulated hot duct to an internally insulated cold casing.

#46 · Cold-to-Cold Framing

Dual internally insulated duct framing keeping both clamping flange interfaces below +60°C.

#47 · Particle Deflector (PD)

Telescopic upstream steel flow liner shielding the fabric cavity from abrasive gas streams up to 45 m/s.

#48 · Condensate Drain (DP & DB)

Bottom gutter and corrosion-resistant drain nozzle evacuating liquid acid pools from wet ducts.

#49 · Single-Axis Particle Barrier (SAPB)

Internal flexible barrier preventing fly ash packing during predominantly axial duct movements.

#50 · Double-Axis Particle Barrier (DAPB)

Floating multi-directional barrier preventing dust compaction during ±150 mm concurrent movements.

#51 · Particle Discharge Pipe (PEB)

Gravity bottom-purging chute discharging accumulated dust from horizontal cement and ESP ducts.

#52 · Flange Heat Dissipation Fins (FK)

Welded carbon steel or AISI 304/310S standoff cooling fins (mechanically clamped Cu/Al ≤250°C) reducing flange clamping temperatures by 100°C–180°C.

#53 · Tadpole Flange Gasket (TG)

Bulb-and-tail refractory sealing gasket providing thermal break and gas tightness under clamping bars.

#54 · Shipping Bars / Transit Brackets

Temporary steel spacers holding design face-to-face length during transport; must be removed before startup.

#55 · Flow Direction Arrow

Permanent directional stamp ensuring internal liners are welded upstream and telescope downstream.

#56 · Fabric Flutter

Aerodynamic membrane oscillation in turbulent high-velocity fan ducts prevented by flow sleeves.

#57 · Vacuum Anti-Collapse Ring

Domed internal stiffening ring preventing inward belt necking under severe negative suction pressure.

#58 · HRSG Inlet Diffuser

Heat Recovery Steam Generator transition zone facing 0°C→+650°C fast-start gas turbine thermal shock.

Technical Guide →

#59 · Peaking Gas Turbine Shock

Rapid startup temperature ramp causing severe thermal gradients across turbine exhaust compensators.

#60 · Air Preheater (APH)

Boiler regenerative heat exchanger requiring multi-layer FlueTec™ compensators on hot flue ducts.

#61 · DeNOx / SCR Duct

Selective Catalytic Reduction flue gas line operating around +320°C–+420°C with ammonia slip.

#62 · Electrostatic Precipitator (ESP)

High-dust particulate collector inlet/outlet duct protected by ArminTec™ and DAPB barriers.

#63 · Cyclone Preheater Riser

Cement kiln suspension preheater duct exposed to abrasive alkaline raw meal and clinker dust.

Technical Guide →

#64 · EAF Canopy Hood

Electric Arc Furnace fume extraction duct enduring cyclic heat surges and metallic spark carryover.

Technical Guide →

#65 · ID / FD / PA Fans

Induced Draft, Forced Draft, and Primary Air industrial blowers isolated by FanTec™ (95% vibration cut).

Technical Guide →

#66 · FanTec™ Series

BundleTec fan vibration isolation fabric joint (-35°C to +250°C, ±15,000 Pa / ±150 mbar).

Technical Guide →

#67 · ChemTec™ Series

BundleTec 100% pure sintered PTFE acid-proof fabric joint (-40°C to +260°C, ±35,000 Pa).

Technical Guide →

#68 · ArminTec™ Series

BundleTec Hardox 400 (≤250°C) & AISI 310S (250–550°C) abrasion-armored fabric joint (-30°C to +550°C, ±15,000 Pa, up to 45 m/s).

Technical Guide →

#69 · FlueTec™ Series

BundleTec CMS-Bio multi-layer boiler flue gas fabric joint (+100°C to +750°C, ±35,000 Pa).

Technical Guide →

#70 · GtTec™ Series

BundleTec Inconel 625 gas turbine thermal-shock fabric joint (+400°C to +1000°C, ±15,000 Pa).

Technical Guide →

#71 · FabricSim™ Solver

BundleTec multi-physics simulator for thermal gradients, acid dew point, kinematics, and 3D CAD.

Technical Guide →

#72 · CyclePro™ Software

BundleTec metallic bellows fatigue and squirm analyzer per EJMA 10/11, EN 14917, and ASME VIII App. 26.

Technical Guide →

#73 · RubberPro™ Software

BundleTec elastomeric expansion joint reliability simulator per DIN 4809, FSA, and 14-mode Weibull frailty.

Technical Guide →

#74 · EJMA 10th / 11th Edition

Expansion Joint Manufacturers Association calculation standard for metallic bellows stress and cycle life.

Technical Guide →

#75 · EN 14917:2009+A1:2012

European harmonized standard for metallic bellows expansion joints under PED 2014/68/EU.

Technical Guide →

#76 · ASME VIII Div. 1 App. 26

Mandatory pressure vessel code governing U-shaped and toroidal metallic expansion joints.

Technical Guide →

#77 · DIN 4809

German pressure-temperature derating and durability standard for elastomeric rubber expansion joints.

#78 · Linear Expansion Coefficient (α)

Material thermal growth rate per meter and degree Celsius (12×10⁻⁶ carbon steel; 16.5×10⁻⁶ AISI 304).

Technical Guide →

#79 · 48-Hour Emergency Turnaround

BundleTec rapid fabrication line delivering custom fabric belts within 48 hours for unplanned outages.

Technical Guide →

#80 · On-Site Belt Replacement

Replacing a worn multi-layer fabric belt on existing standoff frames without cutting steel ductwork.

Technical Guide →