Technical Author & Review:
Nayri Akbuğa · BundleTec Engineering · 2026
Combating Halide Acid Gas & Hygroscopic Alkali Salts
Municipal solid waste (MSW), RDF, and biomass boilers generate flue gas loaded with 500–1500 mg/Nm³ HCl, HF, SO₂, and sticky alkali-chloride ash. During turndown, hygroscopic chloride salts draw moisture and attack metal.
Our hybrid FlueTec™/ChemTec™ architecture combines +750°C thermal insulation with a continuous cross-laminated PTFE barrier rated pH 0–14.
PTFE non-stick surface chemistry reduces sticky fly-ash bridging inside flexing convolutions.
Zero Fugitive Emissions Between Reactors & SCR Units
Strict IED emission rules allow zero uncontrolled HCl or dioxin escape. All flange interfaces use PTFE-enveloped tadpole gaskets and 100% EN 1593 Nekal® tested seams.
On >260°C boiler ducts, leave flanges and clamping bars uninsulated to prevent PTFE overheating. On 130–240°C HCl/H₂SO₄ APC ducts, keep flange steel above acid dew point with controlled tracing or removable jackets under 250°C.
WtE & Biomass Flue Gas Train Selection
WtE & Biomass Flue Gas Train Selection
| Boiler / APC Stage | Thermal & Chemical Hazard | Recommended Series | Design Safeguard |
| Boiler Outlet & Superheater | +400°C / +750°C, alkali ash | FlueTec™ | CMS bolster + Inconel 625 mesh |
| Semi-Dry Lime Reactor | +140°C / +240°C, HCl + lime | ChemTec™ | Non-stick PTFE + DAPB barrier |
| Baghouse & SCR Catalyst Inlet | +130°C / +260°C, HCl/SO₃ | ChemTec™ | EN 1593 ≥50 hPa + Duplex 2205 / 904L / C-276 |
| Biomass ID Fan & Stack | +110°C / +220°C, moist gas | ChemTec™ / FanTec™ | Condensate drain + PTFE cover |
Five WtE & Biomass Rules for Long-Term Corrosion Immunity
- Account for combined HCl + H₂SO₄ dew points and specify pure sintered PTFE gas barriers.
- On >260°C boiler ducts keep flanges air-ventilated; on 130–240°C HCl APC ducts keep flanges above acid dew point (<250°C).
- Add Cavity Pillows downstream of lime injection to stop hardened reagent buildup.
- Upgrade wetted chloride hardware to Duplex 2205, 904L, 254 SMO, or Alloy C-276 (304/316Ti still suffers Cl-SCC above ~60°C).
- Archive EN 1593 Nekal® bubble-test certificates per RAL-GZ 719 in the plant environmental dossier.
Frequently Asked Engineering Questions
Why does standard silicone cloth fail rapidly in WtE flue gas?
Concentrated HCl vapor and acidic chloride salts hydrolyze and embrittle silicone rubbers; pure sintered PTFE is required for lasting service.
How do you prevent low-load dew-point condensation inside the joint?
FabricSim™ models interface temperatures at minimum boiler turndown so the gas barrier stays safely above acid dew point.
How is gas-tightness compliance verified for IED inspections?
Every welded seam is inspected via EN 1593 Nekal® bubble testing at ≥50 hPa per RAL-GZ 719, with optional Helium QA certification.
Recommended Series & Engineering Solvers
Same-Day Custom Engineering Proposal
Share your duct geometry, temperature, and flue gas profile for a RAL-GZ 719 engineered bill of materials.
Launch FabricSim™ →