SECTOR ENGINEERING // INDUSTRIAL FANS & AIR HANDLING

Industrial Fans & Air Handling Fabric Expansion Joints

Vibration-isolating FanTec™ joints rated to ±15,000 Pa (±150 mbar) for FD, ID, primary air, and baghouse exhaust fans.

Technical Author & Review: Nayri Akbuğa · BundleTec Engineering · 2026

Protecting Fan Bearings with Negligible Belt Spring Rates

Centrifugal and axial industrial fans excite continuous 15–120 Hz blade-pass vibration. Rigid duct tie-ins transmit dynamic loads directly into casing flanges and shorten bearing L10 life.

FanTec™ operates from -35°C to +250°C at ±15,000 Pa (±150 mbar). Negligible belt spring stiffness (~10–50 N/m perimeter vs. 500–5,000 N/mm for metal bellows) relieves nozzle moments, while duct anchors still react pressure thrust (P × A).

One compact 150–250 mm gap absorbs thermal expansion, vibration, and field installation misalignment simultaneously.

Eliminating Aerodynamic Flutter & Duct-Borne Noise

High discharge velocity and fan pulsation cause oversized belts to flutter violently. Precisely sizing developed belt width (W_dev) per FSA-DSJ keeps the belt taut without over-tensioning.

Where workplace noise limits apply, an optional acoustic fiberglass bolster trims radiated duct noise by 15–20 dB.

FanTec™ Design Matrix by Fan Duty

FanTec™ Design Matrix by Fan Duty
Fan ServicePressure & TempElastomer CoatingPrimary Objective
Forced Draft (FD) Air Fan+20°C / +120°C, +15,000 PaFanTec™ Silicone / EPDMVibration isolation & zero flutter
Induced Draft (ID) Flue Fan+100°C / +250°C, -15,000 PaFanTec™ Silicone (≤240°C cont. / +250°C int., dry gas) / FKM (≤204°C) · ChemTec™ PTFE (≤260°C, acid fumes)Suction stability & chemical duty (ChemTec™ for acid)
Baghouse Exhaust Fan-20°C / +180°C, ±12,000 PaFanTec™ + Light BaffleParticulate shielding & alignment
Marine & Acoustic HVAC-35°C / +135°C, ±8,000 PaFanTec™ Acoustic Pillow15–20 dB noise attenuation

Five Engineering Rules for Fan Inlet & Discharge Joints

  • Size free gap (L0) conservatively on -15,000 Pa suction inlets to prevent inward draw.
  • Add spring-isolator startup displacement to thermal movement when sizing belt movement capacity.
  • Specify a short upstream flow liner above 15–20 m/s clean air (mandatory >25 m/s, or ≥10–15 m/s with dust >10 g/Nm³).
  • Space backup-bar clamping bolts every 80–100 mm for uniform gasket compression.
  • Never wrap external lagging over elastomer belts; outer skin must dissipate heat to ambient air.

Frequently Asked Engineering Questions

What is the standard design pressure rating for FanTec™?

FanTec™ is standardized to ±15,000 Pa (±150 mbar) positive and negative design pressure across all production builds.

Will continuous fan vibration fatigue the fabric belt?

No. Silicone, EPDM, and FKM coated fiberglass/aramid fabrics pass ISO 132 flex-cracking and DIN 53508 thermal aging for millions of cycles.

Should I specify U-Type or Flat Belt on fan connections?

U-Type works best for compact bolted flange gaps on clean air fans; Flat Belt excels on large rectangular or irregular retrofits.

Recommended Series & Engineering Solvers

Same-Day Custom Engineering Proposal

Share your duct geometry, temperature, and flue gas profile for a RAL-GZ 719 engineered bill of materials.

Launch FabricSim™ →