GEOMETRY ENGINEERING // FSA-DSJ & RAL-GZ 719

U-Type vs. Flat Belt vs. Cavity Pillow Geometries

Selecting the right structural profile by flange layout, displacement amplitude, particulate loading, and outage window.

Technical Author & Review: Nayri Akbuğa · BundleTec Engineering · 2026

Pre-Molded U-Type vs. Flat Belt with Backup Bars

A U-Type belt features molded integral mounting flanges clamped directly between opposing duct flanges. It delivers a tidy, low-profile seal across short 120–200 mm gaps on clean fan ducts.

A Flat Belt clamps onto cylindrical or rectangular steel stand-offs using rounded backup bars. With zero mold constraints, it scales past 30 m perimeter and installs open-ended around intact ducts.

Developed belt width (W_dev) on flat belts is computed directly from combined axial, lateral, and angular vectors per FSA-DSJ.

Integrated Cavity Pillow / Bolster Architecture

Above +300°C or in dust-laden cement and power ducts, a separate removable Cavity Pillow (bolster) fills the gap between internal baffle and outer belt.

The pillow drops hot-face temperature safely below elastomer limits while physically blocking ash and clinker powder from packing the cavity.

Comparison of U-Type, Flat Belt & Cavity Pillow Profiles

Comparison of U-Type, Flat Belt & Cavity Pillow Profiles
Geometry ProfileBest-Fit ApplicationKey AdvantageDesign Constraint
U-Type (Flanged Belt)Clean fans, HVAC, compact gaps (≤250°C FanTec™ / ≤260°C ChemTec™)Minimal steel frame, neat bolted sealCorner molding on huge rectangles
Flat Belt (Clamped)Flue ducts, wide rectangles, retrofitsUnlimited size, 4-hr open-ended spliceRequires R ≥ 3 mm backup bars
Cavity Pillow (Bolster)>300°C hot gas, cement, HRSG, EAFThermal drop + zero dust packingPair with internal flow sleeve

Five Geometry Selection Rules for Engineers

  • Specify open-ended Flat Belts when replacing worn belts without disassembling steel ductwork.
  • Mandate removable Cavity Pillows plus flow liners whenever gas exceeds +300°C or 5 g/Nm³ dust.
  • Round all clamping bar and stand-off edges to R ≥ 3 mm to prevent flex-line belt cutting.
  • Check maximum axial compression (-Δx) clearance against the flow sleeve in FabricSim™.
  • Add bottom drain ports on wet horizontal U-Type belts so condensate cannot pool in the fold.

Frequently Asked Engineering Questions

Is a field-spliced open-ended flat belt as gas-tight as an endless factory belt?

Yes. Controlled 370°C PTFE thermal welding or hot FKM/silicone vulcanization achieves ≥85% joint efficiency and full tightness.

Can the Cavity Pillow bolster be replaced independently from the outer belt?

Yes. Bolster cartridges and gas-seal belts are independent modules, lowering recurring overhaul costs.

How do I calculate developed flat belt width (W_dev)?

Use our free Thermal Duct Expansion Calculator or FabricSim™ to compute exact W_dev from installation gap L0 and 3-axis movements.

Recommended Series & Engineering Solvers

Same-Day Custom Engineering Proposal

Share your duct geometry, temperature, and flue gas profile for a RAL-GZ 719 engineered bill of materials.

Launch FabricSim™ →