Abrasion-Resistant Fabric Expansion Joint Manufacturing (ArminTec™)
ArminTec armored fabric expansion joints resist heavy particulate erosion. Deflector liners use Hardox 400 (≤250°C) or AISI 304/310S (250–550°C). Rated for -30°C to +550°C and ±15,000 Pa.
ArminTec abrasion-resistant joints serve cement plants, coal stations, and steel mills. They absorb thermal expansion and misalignment in heavily dust-laden ducts. Product code FEXJ-ARM integrates a telescopic internal deflector baffle. Hardox 400 (≤250°C) or AISI 304/310S (250–550°C) shields composite layers from erosion.
ArminTec operates from -30°C to +550°C at ±15,000 Pa. It delivers ±30% axial and ±15% lateral movement capacity. Its ceramic bolster and multi-layer seal prevent dust packing. Internal baffles protect the belt up to 45 m/s flow velocity.
Multi-Axial Movement & Anchor Load Reduction Analysis
Analyze simultaneous axial compression and lateral deflection, evaluating significant structural anchor savings vs metal bellows.
Overview
ArminTec™ armored fabric expansion joints resist severe dust erosion in cement, coal, and steel ducts up to +550°C. Tiered deflectors pair Hardox 400 (≤250°C) or AISI 304/310S (250–550°C) with particle barriers. See Extending Expansion Joint Lifecycle.
Areas of Use
- Cement Plant Cyclone Outlets
- Thermal Plant Coal & Fly Ash Lines
- Steel Mill Abrasive Gas Ducts
- Cyclone & ESP Precipitator Inlets
Technical Specifications
ArminTec series operates at -30°C to +550°C and ±15,000 Pa (±150 mbar) pressure. It absorbs ±30% axial and ±15% lateral movement, with Hardox 400 (≤250°C) or AISI 304/310S (250–550°C) deflectors against abrasive particulates.
ArminTec™ Technical Parameters & Operating Thresholds
| Layer Architecture | 4 Layers (Internal flow sleeve + ceramic bolster + gas seal barrier + outer jacket) |
| Internal Deflector Sleeve | Telescopic flow baffle: Hardox 400/500 (≤250°C) or AISI 304 / EN 1.4828 / AISI 310S (1.4845) (250–550°C) |
| Abrasive Erosion Resistance | Full resistance to cement clinker dust, coal fly ash, and metallic particulates |
| Compliance Standards | FSA Non-Metallic Handbook (Chapters 4 & 5) · RAL-GZ 719 · DIN EN ISO 13934-1 |
| Engineering Revision | REV.2026.1 · ISO 9001 · 14001 · 45001 · 10002 Certified Manufacturing |
Calculate your duct expansion and select the ideal series →
Input your duct dimensions, design temperatures, and multi-axial displacements to calculate the required belt width (W_dev) and anchor force savings.
Applicable International Quality & Manufacturing Standards
All our fabric expansion joint series are engineered, fabricated, and tested referencing European and global non-metallic standards.
Official RAL-GZ 719 (March 2017) governs single and multi-layer designs. Baseline tests cover EN 1593 Nekal® (≥50 hPa), DIN 53508, and ISO 13934-1.
The FSA Non-Metallic Handbook (Chapters 4 & 5) sets clamping and torque rules. It specifies R ≥ 3 mm radii and 10–12% belt slack.
Zone 1/21 and 2/22 ducts use conductive PTFE (Rs < 10⁶ Ω). Equipotential bonding jumpers and T-Class surface limits ensure explosion safety.
Field Reference Projects & Case Studies
Real-world installation and operational performance records across heavy industrial facilities.
Installation Gap (L_inst) Movement Reference & EPC Traceability
This reference table summarizes typical multi-axial movement capacities across standard installation gaps. Exact developed belt width (W_dev) is verified per duct geometry.
| Installation Gap (L_inst) | Axial Compression | Axial Extension | Lateral Movement (±) | Angular (±) | Typical Profile |
|---|---|---|---|---|---|
| 150 mm | -45 mm | +15 mm | ±22 mm | ±5° | U-Type or Compact Flat Belt |
| 200 mm | -60 mm | +20 mm | ±30 mm | ±5° | U-Type / Standard Flat Belt |
| 250 mm | -75 mm | +25 mm | ±38 mm | ±5° | Standard Flat Belt / Insulated |
| 300 mm | -90 mm | +30 mm | ±45 mm | ±5° | High-Temp Multi-Layer Bolster |
| 400 mm | -120 mm | +40 mm | ±60 mm | ±5° | Large Multi-Axial Power / HRSG |
EPC Quality Assurance & Traceability Package
- Mill Certificates: EN 10204 2.2 covers textiles and elastomers. EN 10204 3.1 covers steel frames, liners, and bolting.
- Alloy & Welding QA: Positive Material Identification (PMI) and WPS/WPQR qualification apply to fabricated alloy frames.
- Factory Tightness FAT: Every seam passes RAL-GZ 719 EN 1593 Nekal® (≥50 hPa) bubble testing. Optional Helium QA is available.
Custom Fabrication & Quality Assurance Flow
Every BundleTec fabric expansion joint is custom built at our Istanbul manufacturing facility. Each step from raw material intake to final inspection follows ISO 9001:2015 traceability. Multi-layer cutting, PTFE welding, and bolster assembly happen under one roof.
- Operating gas chemistry, temperature, pressure, and movements are modeled in FabricSim™.
- Virgin PTFE foils, silica fabrics, and CMS-Bio bolsters are drawn from strategic stock.
- Corner transitions receive heat-welded seams and aramid stitching for high-integrity gas-tight sealing.
- RAL-GZ 719 (EN 1593 Nekal® ≥50 hPa bubble test), optional BundleTec Helium QA, and DIN EN ISO 13934-1 tensile checks verify quality.
- Standard global shipping or 48-hour emergency dispatch minimizes outage downtime.
Related resources: Steel-Framed Fabric Joint Case Study · FanTec Vacuum Case Study · Near-Zero Leakage Guide.
Selection & RFQ guides: Pricing & RFQ Guide · Fabric vs. Metal Joints · Fabric vs. Rubber (DIN 4809).