FanTec ChemTec ArminTec FlueTec GtTec
ARMINTEC ABRASION RESISTANT SERIES

Abrasion-Resistant Fabric Expansion Joint Manufacturing (ArminTec™)

ArminTec armored fabric expansion joints resist heavy particulate erosion. Deflector liners use Hardox 400 (≤250°C) or AISI 304/310S (250–550°C). Rated for -30°C to +550°C and ±15,000 Pa.

ArminTec abrasion-resistant joints serve cement plants, coal stations, and steel mills. They absorb thermal expansion and misalignment in heavily dust-laden ducts. Product code FEXJ-ARM integrates a telescopic internal deflector baffle. Hardox 400 (≤250°C) or AISI 304/310S (250–550°C) shields composite layers from erosion.

ArminTec operates from -30°C to +550°C at ±15,000 Pa. It delivers ±30% axial and ±15% lateral movement capacity. Its ceramic bolster and multi-layer seal prevent dust packing. Internal baffles protect the belt up to 45 m/s flow velocity.

ArminTec Multi-Layered Fabric Expansion Joint (Cloth Compensator)
ENGINEERING TOOL

Multi-Axial Movement & Anchor Load Reduction Analysis

Analyze simultaneous axial compression and lateral deflection, evaluating significant structural anchor savings vs metal bellows.

📐 Calculate Multi-Axial Movements → 📜 FSA-DSJ Torquing Guide

Overview

ArminTec™ armored fabric expansion joints resist severe dust erosion in cement, coal, and steel ducts up to +550°C. Tiered deflectors pair Hardox 400 (≤250°C) or AISI 304/310S (250–550°C) with particle barriers. See Extending Expansion Joint Lifecycle.

Areas of Use

  • Cement Plant Cyclone Outlets
  • Thermal Plant Coal & Fly Ash Lines
  • Steel Mill Abrasive Gas Ducts
  • Cyclone & ESP Precipitator Inlets

Technical Specifications

ArminTec series operates at -30°C to +550°C and ±15,000 Pa (±150 mbar) pressure. It absorbs ±30% axial and ±15% lateral movement, with Hardox 400 (≤250°C) or AISI 304/310S (250–550°C) deflectors against abrasive particulates.

TECHNICAL SPECIFICATIONS MATRIX // REV.2026.1

ArminTec™ Technical Parameters & Operating Thresholds

Operating Temperature
-30°C to +550°C
Peak +600°C (≤15 min)
Design Pressure
±15,000 Pa
±150 mbar design pressure
Axial Movement
±30%
High axial stroke absorption
Lateral Movement
±15%
Multi-plane shear flex
Wear Deflector Liner
Hardox / 310S
≤250°C Hardox · 250–550°C 310S
Max Gas Velocity
≤ 45 m/s
With internal deflector sleeve
Technical Specifications & Engineering Data Matrix
Layer Architecture 4 Layers (Internal flow sleeve + ceramic bolster + gas seal barrier + outer jacket)
Internal Deflector Sleeve Telescopic flow baffle: Hardox 400/500 (≤250°C) or AISI 304 / EN 1.4828 / AISI 310S (1.4845) (250–550°C)
Abrasive Erosion Resistance Full resistance to cement clinker dust, coal fly ash, and metallic particulates
Compliance Standards FSA Non-Metallic Handbook (Chapters 4 & 5) · RAL-GZ 719 · DIN EN ISO 13934-1
Engineering Revision REV.2026.1 · ISO 9001 · 14001 · 45001 · 10002 Certified Manufacturing
📐 MULTI-AXIAL DUCT SIZING

Calculate your duct expansion and select the ideal series →

Input your duct dimensions, design temperatures, and multi-axial displacements to calculate the required belt width (W_dev) and anchor force savings.

Launch Thermal Calculator →
ENGINEERING STANDARDS & QUALITY ASSURANCE

Applicable International Quality & Manufacturing Standards

All our fabric expansion joint series are engineered, fabricated, and tested referencing European and global non-metallic standards.

RAL-GZ 719 Technical Guidance →

Official RAL-GZ 719 (March 2017) governs single and multi-layer designs. Baseline tests cover EN 1593 Nekal® (≥50 hPa), DIN 53508, and ISO 13934-1.

FSA-DSJ Ducting Standards →

The FSA Non-Metallic Handbook (Chapters 4 & 5) sets clamping and torque rules. It specifies R ≥ 3 mm radii and 10–12% belt slack.

ATEX 2014/34/EU Directive →

Zone 1/21 and 2/22 ducts use conductive PTFE (Rs < 10⁶ Ω). Equipotential bonding jumpers and T-Class surface limits ensure explosion safety.

STANDARD L_inst MOVEMENT MATRIX & EPC QUALITY DOSSIER

Installation Gap (L_inst) Movement Reference & EPC Traceability

This reference table summarizes typical multi-axial movement capacities across standard installation gaps. Exact developed belt width (W_dev) is verified per duct geometry.

Standard Installation Gap Movement Capacity Reference Table
Installation Gap (L_inst) Axial Compression Axial Extension Lateral Movement (±) Angular (±) Typical Profile
150 mm -45 mm +15 mm ±22 mm ±5° U-Type or Compact Flat Belt
200 mm -60 mm +20 mm ±30 mm ±5° U-Type / Standard Flat Belt
250 mm -75 mm +25 mm ±38 mm ±5° Standard Flat Belt / Insulated
300 mm -90 mm +30 mm ±45 mm ±5° High-Temp Multi-Layer Bolster
400 mm -120 mm +40 mm ±60 mm ±5° Large Multi-Axial Power / HRSG

EPC Quality Assurance & Traceability Package

  • Mill Certificates: EN 10204 2.2 covers textiles and elastomers. EN 10204 3.1 covers steel frames, liners, and bolting.
  • Alloy & Welding QA: Positive Material Identification (PMI) and WPS/WPQR qualification apply to fabricated alloy frames.
  • Factory Tightness FAT: Every seam passes RAL-GZ 719 EN 1593 Nekal® (≥50 hPa) bubble testing. Optional Helium QA is available.
EPC Quality Dossier (ITP / FAT) PDF → Field Splicing & Vulcanization SOP PDF →

Custom Fabrication & Quality Assurance Flow

Every BundleTec fabric expansion joint is custom built at our Istanbul manufacturing facility. Each step from raw material intake to final inspection follows ISO 9001:2015 traceability. Multi-layer cutting, PTFE welding, and bolster assembly happen under one roof.

  1. Operating gas chemistry, temperature, pressure, and movements are modeled in FabricSim™.
  2. Virgin PTFE foils, silica fabrics, and CMS-Bio bolsters are drawn from strategic stock.
  3. Corner transitions receive heat-welded seams and aramid stitching for high-integrity gas-tight sealing.
  4. RAL-GZ 719 (EN 1593 Nekal® ≥50 hPa bubble test), optional BundleTec Helium QA, and DIN EN ISO 13934-1 tensile checks verify quality.
  5. Standard global shipping or 48-hour emergency dispatch minimizes outage downtime.

Related resources: Steel-Framed Fabric Joint Case Study · FanTec Vacuum Case Study · Near-Zero Leakage Guide.

Selection & RFQ guides: Pricing & RFQ Guide · Fabric vs. Metal Joints · Fabric vs. Rubber (DIN 4809).

FAQ // Engineering Knowledge Base

Frequently Asked Questions

What operating temperatures and abrasive conditions does ArminTec handle? +

ArminTec operates from -30°C to +550°C continuously. It features an integrated Hardox 400/500 (≤250°C) or AISI 304 / AISI 310S (250–550°C) internal deflector liner to resist aggressive particle erosion in cement cyclones and coal ash ducts.

What is the function of the internal wire mesh bolster in ArminTec expansion joints? +

The woven Inconel 625 or stainless steel wire mesh provides dimensional stability under -30°C to +550°C thermal cycles

What maintenance and turnaround advantages does the ArminTec series offer? +

Unlike metallic bellows, the fabric belt can be inspected and replaced from outside the duct within 48 hours without cutting structural pipework, drastically reducing outage costs.

How does ArminTec absorb simultaneous multi-axial movements? +

Its multi-layered composite matrix absorbs concurrent axial compression, 100+ mm lateral shear, and angular tilt without transmitting mechanical stresses to duct anchors.