Field Problem / Customer Requirement
A heavy process dust-extraction plant faced an emergency requirement for 32 circular DN 1200 (Ø1,200 mm) fan intake joints. Operating at -15,000 Pa vacuum and +220°C continuous air temperature, the plant required full batch shipment within 48 hours.
BundleTec Innovation and Engineering Solution
BundleTec fabricated 32 domed-profile FanTec™ fabric expansion joints for L_inst = 200 mm with integrated AISI 304 internal vacuum rings. Multi-ply silicone-coated E-glass belts provide +240°C continuous rating.
The internal anti-collapse ring blocks belt inversion at -15,000 Pa vacuum. It preserves ±30 mm axial and ±18 mm lateral flexibility.
All 32 units passed EN 1593 Nekal® (≥50 hPa) and vacuum-collapse testing. Full batch dispatch completed within 48 hours.
Do you have a similar process problem?
Consult Our Lead Engineers Now →Related Fabric Expansion Joint Series & FabricSim™ Simulation
For industrial fan suction and discharge lines requiring 95% vibration isolation and ±15,000 Pa vacuum stability, explore FanTec™ Series. Validate duct movements in FabricSim™.