FanTec™ Fabric Expansion Joint – High Vacuum Resistance and Fast Delivery
CASE STUDY

FanTec™ Fabric Expansion Joint – High Vacuum Resistance and Fast Delivery

Field Problem / Customer Requirement

A heavy process dust-extraction plant faced an emergency requirement for 32 circular DN 1200 (Ø1,200 mm) fan intake joints. Operating at -15,000 Pa vacuum and +220°C continuous air temperature, the plant required full batch shipment within 48 hours.

BundleTec Innovation and Engineering Solution

BundleTec fabricated 32 domed-profile FanTec™ fabric expansion joints for L_inst = 200 mm with integrated AISI 304 internal vacuum rings. Multi-ply silicone-coated E-glass belts provide +240°C continuous rating.

The internal anti-collapse ring blocks belt inversion at -15,000 Pa vacuum. It preserves ±30 mm axial and ±18 mm lateral flexibility.

All 32 units passed EN 1593 Nekal® (≥50 hPa) and vacuum-collapse testing. Full batch dispatch completed within 48 hours.

Do you have a similar process problem?

Consult Our Lead Engineers Now →
Share:
BundleTec

Field Engineering Parameters & Verification Matrix

This FanTec™ joint was custom engineered at our plant for exact pressure, temperature, and duct movements. Before fabrication, multi-layer thermal drop and liner clearances were verified in FabricSim™.

Project Engineering & Field Verification Matrix
Engineering ParameterVerified Field Specification
Product SeriesFanTec™
Plant & Duct LocationHeavy Process Dust Extraction · 32 Circular Fan Lines
Duct Cross-Section & L_inst32 Units × DN 1200 (Ø1,200 mm) · L_inst = 200 mm
Operating & Peak Temperature-20°C to +220°C Continuous (Silicone E-Glass +240°C Rated)
Design Pressure & Gas Velocity-15,000 Pa (-150 mbar) Vacuum / ±15,000 Pa Rated
Process MediumHigh-Vacuum Process Air & Baghouse Fan Suction
Composite & Frame ArchitectureDomed Multi-Ply Silicone E-Glass Belt + Internal AISI 304 Anti-Collapse Vacuum Ring
Movement Envelope±30 mm Axial · ±18 mm Lateral
Verified Field Outcome32 Custom Units Fabricated, Tested & Dispatched in 48 Hours
Quality & Leak VerificationRAL-GZ 719 (EN 1593 Nekal® ≥50 hPa) + Vacuum Collapse Proof + FSA Handbook