Acid and Chemical Resistant PTFE Fabric Expansion Joint (ChemTec™)
ChemTec 100% virgin PTFE fabric expansion joints seal wet FGD and chemical ducts. They operate continuously from -40°C to +260°C at ±35,000 Pa.
ChemTec multi-layer fabric expansion joints (cloth compensators) solve thermal expansion, vibration, and misalignment problems in chemically aggressive ductwork. Defined by product code FEXJ-CHEM, these expansion joints deliver reliable, long-lasting operation. Built for chemical and petrochemical plants, ChemTec joints stabilize corrosive ducting. They cut maintenance costs and extend campaign uptime.
These expansion joints stand out with their high resistance to acids and chemical substances. ChemTec performs reliably in both dry and wet chemical streams. Its flexible composite build absorbs multi-axis movement safely. It adapts to different installation needs with optional flanged or clamped models, simplifying integration across industrial duct applications.
Acid Dew Point & 60+ Chemical Resistance Matrix
Analyze PTFE, FKM, and silicone chemical limits interactively. Check resistance against H₂SO₄, HCl, HF, SO₂, and wet condensation.
Overview
ChemTec multi-layer fabric expansion joints maximize reliability in corrosive lines. Their high-integrity, near-zero-emission gas-tight design (EN 1593 Nekal® ≥50 hPa) supports energy-efficient and compliant operations. Developed for aggressive chemical environments, this product does not compromise its performance even during long-term use. To discover how non-metallic solutions solve severe acid corrosion challenges, see our overview of Fabric Expansion Joints Benefits.
Usage Areas
- Wet & Semi-Dry FGD Flue Gas Desulfurization Scrubbers
- Sulfuric Acid (H₂SO₄), Hydrochloric Acid (HCl) & Fertilizer Plants
- Waste-to-Energy (WtE) Acid-Gas Filtration & SCR Lines
- Sub-Acid-Dew-Point Saturated Corrosive Gas Ducts (pH 0–14)
Technical Specifications
ChemTec series provides 100% virgin PTFE gas barrier at -40°C to +260°C and ±35,000 Pa (±350 mbar) pressure. It delivers -25%/+15% axial and ±10% lateral flexibility with full pH 0–14 resistance.
ChemTec™ Technical Parameters & Operating Thresholds
| Layer Architecture | Uninsulated Multi-Ply PTFE Composite (PTFE-glass carrier scrim, 100% sintered virgin PTFE gas barrier, PTFE/FKM outer weather cover — no fibrous thermal bolster) |
| Max Gas Velocity | ≤ 25 m/s (Wet corrosive acid vapor conditions) |
| Chemical Compatibility | H2SO4, HCl, HNO3, HF and all wet FGD flue gas condensates |
| Compliance Standards | FSA-DSJ-401 (FKM) · RAL-GZ 719 · DIN EN ISO 13934-1 |
| Engineering Revision | REV.2026.1 · ISO 9001 · 14001 · 45001 · 10002 Certified Manufacturing |
Calculate your duct expansion and select the ideal series →
Input your duct dimensions, design temperatures, and multi-axial displacements to calculate the required belt width (W_dev) and anchor force savings.
Applicable International Quality & Manufacturing Standards
All our fabric expansion joint series are engineered, fabricated, and tested referencing European and global non-metallic standards.
Official RAL-GZ 719 (March 2017) governs single and multi-layer designs. Baseline tests cover EN 1593 Nekal® (≥50 hPa), DIN 53508, and ISO 13934-1.
FSA-DSJ-401 governs acid-resistant terpolymer FKM fluoroelastomers. The FSA Non-Metallic Handbook (Chapters 4 & 5) sets clamping torques and 10–12% slack.
Zone 1/21 and 2/22 ducts use conductive PTFE (Rs < 10⁶ Ω). Equipotential bonding jumpers and T-Class surface limits ensure explosion safety.
Field Reference Projects & Case Studies
Real-world installation and operational performance records across heavy industrial facilities.
Installation Gap (L_inst) Movement Reference & EPC Traceability
This reference table summarizes typical multi-axial movement capacities across standard installation gaps. Exact developed belt width (W_dev) is verified per duct geometry.
| Installation Gap (L_inst) | Axial Compression | Axial Extension | Lateral Movement (±) | Angular (±) | Typical Profile |
|---|---|---|---|---|---|
| 150 mm | -45 mm | +15 mm | ±22 mm | ±5° | U-Type or Compact Flat Belt |
| 200 mm | -60 mm | +20 mm | ±30 mm | ±5° | U-Type / Standard Flat Belt |
| 250 mm | -75 mm | +25 mm | ±38 mm | ±5° | Standard Uninsulated Flat Belt |
| 300 mm | -90 mm | +30 mm | ±45 mm | ±5° | Wide-Span Uninsulated Belt |
| 400 mm | -120 mm | +40 mm | ±60 mm | ±5° | Large-Section Duct Belt (Uninsulated) |
EPC Quality Assurance & Traceability Package
- Mill Certificates: EN 10204 2.2 covers textiles and elastomers. EN 10204 3.1 covers steel frames, liners, and bolting.
- Alloy & Welding QA: Positive Material Identification (PMI) and WPS/WPQR qualification apply to fabricated alloy frames.
- Factory Tightness FAT: Every seam passes RAL-GZ 719 EN 1593 Nekal® (≥50 hPa) bubble testing. Optional Helium QA is available.
Custom Fabrication & Quality Assurance Flow
Every BundleTec fabric expansion joint is custom built at our Istanbul manufacturing facility. Each step from raw material intake to final inspection follows ISO 9001:2015 traceability. Multi-ply cutting, chemical barrier lamination, and continuous sintered PTFE welding happen under one roof.
- Operating gas chemistry, temperature, pressure, and movements are modeled in FabricSim™.
- High-tenacity E-glass, silicone, EPDM, and sintered PTFE stocks enable fast build.
- Corner transitions receive heat-welded seams and aramid stitching for high-integrity gas-tight sealing.
- RAL-GZ 719 (EN 1593 Nekal® ≥50 hPa bubble test), optional BundleTec Helium QA, and DIN EN ISO 13934-1 tensile checks verify quality.
- Standard global shipping or 48-hour emergency dispatch minimizes outage downtime.
Related resources: Steel-Framed Fabric Joint Case Study · FanTec Vacuum Case Study · Near-Zero Leakage Guide.
Selection & RFQ guides: Pricing & RFQ Guide · Fabric vs. Metal Joints · Fabric vs. Rubber (DIN 4809).