FanTec ChemTec ArminTec FlueTec GtTec
FLUETEC FLUE GAS & BOILER SERIES

Boiler and Flue Gas Fabric Expansion Joint Manufacturing (FlueTec™)

FlueTec multi-layer composite fabric expansion joints deliver high thermal insulation for power boilers, air preheaters (APH), and flue gas ducts at +100°C to +750°C and ±35,000 Pa.

FlueTec multi-layer fabric expansion joints (cloth compensators) offer superior performance against thermal expansion and displacement problems encountered by pipe and duct systems in demanding industrial environments with high temperatures and high flow velocities. Defined by Product Code: FEXJ-FLUE, these expansion joints are specifically designed for power plants, the steel industry, and other high-temperature applications. They increase the reliability of your systems, ensuring long-lasting and uninterrupted operation.

Thanks to its multi-layer structure, FlueTec multi-layer fabric expansion joints (cloth compensators) offer both durability and flexibility. With the ability to dampen movement in multiple axes, it effectively absorbs stresses generated in your systems. Optimized for use in dry environments, this product also provides protection against chemical effects with moderate acid resistance. With optional steel-framed models, it adapts to different industrial needs, offering ease of installation and system integration.

FlueTec Multi-Layered Fabric Expansion Joint (Cloth Compensator)
ENGINEERING TOOL

Flue Gas Thermal Expansion & Particulate Deflector Sizing

Calculate +750°C thermal growth in coal-fired boilers and cement kilns, determining the required developed belt width (W_dev).

📐 Calculate Flue Duct Expansion → 📜 RAL-GZ 719 Technical Guidance

Overview

FlueTec™ multi-layer fabric expansion joints insulate hot boiler and flue gas ducts up to +750°C. A 1200°C CMS-Bio bolster protects the PTFE gas barrier and keeps outer skin below 60°C. Learn more in our Heat-Resistant Fabric Guide.

Areas of Use

  • Thermal Power Plant Boiler Ducts
  • Air Preheater (APH) Transitions
  • DeNOx / SCR Flue Gas Ducts
  • Industrial Boiler Exhaust Systems

Technical Specifications

FlueTec series operates at +100°C to +750°C and ±35,000 Pa (±350 mbar) pressure. It absorbs -25%/+15% axial and ±20% lateral movement, with 1200°C CMS-Bio bolster insulation for boiler exhaust ducts.

TECHNICAL SPECIFICATIONS MATRIX // REV.2026.1

FlueTec™ Technical Parameters & Operating Thresholds

Operating Temperature
+100°C to +750°C
Peak +800°C (≤30 min)
Design Pressure
±35,000 Pa
±350 mbar high pressure
Axial Movement
-25% / +15%
Thermal stroke absorption
Lateral Movement
±20%
Boiler multi-plane shear
Thermal Bolster
1200°C CMS-Bio
Ecological soluble fiber
Max Gas Velocity
≤ 40 m/s
High flue gas volume
Technical Specifications & Engineering Data Matrix
Layer Architecture 5 Layers (High-temperature fabric + CMS-Bio bolster + PTFE barrier + outer jacket)
Thermal Insulation Core 1200°C rated biosoluble CMS-Bio ecological fiber bolster
Gas Sealing Membrane High-temperature chemically resistant laminated fluoropolymer barrier
Compliance Standards FSA Non-Metallic Handbook (Chapters 4 & 5) · RAL-GZ 719 · DIN EN ISO 13934-1
Engineering Revision REV.2026.1 · ISO 9001 · 14001 · 45001 · 10002 Certified Manufacturing
FlueTec Fabric Expansion Joint 3D CAD Cross-Section Detail (Flange, Clamping Bar, Fabric Layer)
📐 STEP + STL
🔍 3D CAD Detail — Click & Download 2.2 MB RAR
Click on the preview to download 3D CAD and 3D printing model files.
📐 3D ENGINEERING & CAD ASSETS

FlueTec 3D CAD & 3D Print Model Package

Integrate full-scale 3D CAD solid models and 3D print-ready STL files of the FlueTec flanged fabric expansion joint directly into your project. Complete with duct flanges, clamping flat bars, hardware, thermal bolster, and multi-layer fabric sealing belt.

Formats
STEP + STL
Package Size
2.26 MB (.rar)
Bonus Content
360° Video + HD CAD
CAD Support
SolidWorks / Inventor
Included Components:
✓ Right & Left Duct Flanges ✓ Clamping Flat Bars ✓ Multi-Layer Fabric Belt ✓ Thermal Insulation Bolster
📐 MULTI-AXIAL DUCT SIZING

Calculate your duct expansion and select the ideal series →

Input your duct dimensions, design temperatures, and multi-axial displacements to calculate the required belt width (W_dev) and anchor force savings.

Launch Thermal Calculator →
STANDARD L_inst MOVEMENT MATRIX & EPC QUALITY DOSSIER

Installation Gap (L_inst) Movement Reference & EPC Traceability

This reference table summarizes typical multi-axial movement capacities across standard installation gaps. Exact developed belt width (W_dev) is verified per duct geometry.

Standard Installation Gap Movement Capacity Reference Table
Installation Gap (L_inst) Axial Compression Axial Extension Lateral Movement (±) Angular (±) Typical Profile
150 mm -45 mm +15 mm ±22 mm ±5° U-Type or Compact Flat Belt
200 mm -60 mm +20 mm ±30 mm ±5° U-Type / Standard Flat Belt
250 mm -75 mm +25 mm ±38 mm ±5° Standard Flat Belt / Insulated
300 mm -90 mm +30 mm ±45 mm ±5° High-Temp Multi-Layer Bolster
400 mm -120 mm +40 mm ±60 mm ±5° Large Multi-Axial Power / HRSG

EPC Quality Assurance & Traceability Package

  • Mill Certificates: EN 10204 2.2 covers textiles and elastomers. EN 10204 3.1 covers steel frames, liners, and bolting.
  • Alloy & Welding QA: Positive Material Identification (PMI) and WPS/WPQR qualification apply to fabricated alloy frames.
  • Factory Tightness FAT: Every seam passes RAL-GZ 719 EN 1593 Nekal® (≥50 hPa) bubble testing. Optional Helium QA is available.
EPC Quality Dossier (ITP / FAT) PDF → Field Splicing & Vulcanization SOP PDF →

Custom Fabrication & Quality Assurance Flow

Every BundleTec fabric expansion joint is custom built at our Istanbul manufacturing facility. Each step from raw material intake to final inspection follows ISO 9001:2015 traceability. Multi-layer cutting, PTFE welding, and bolster assembly happen under one roof.

  1. Operating gas chemistry, temperature, pressure, and movements are modeled in FabricSim™.
  2. Virgin PTFE foils, silica fabrics, and CMS-Bio bolsters are drawn from strategic stock.
  3. Corner transitions receive heat-welded seams and aramid stitching for high-integrity gas-tight sealing.
  4. RAL-GZ 719 (EN 1593 Nekal® ≥50 hPa bubble test), optional BundleTec Helium QA, and DIN EN ISO 13934-1 tensile checks verify quality.
  5. Standard global shipping or 48-hour emergency dispatch minimizes outage downtime.

Related resources: Steel-Framed Fabric Joint Case Study · FanTec Vacuum Case Study · Near-Zero Leakage Guide.

Selection & RFQ guides: Pricing & RFQ Guide · Fabric vs. Metal Joints · Fabric vs. Rubber (DIN 4809).

FAQ // Engineering Knowledge Base

Frequently Asked Questions

What temperature range and boiler applications is FlueTec designed for? +

FlueTec is engineered for +100°C to +750°C continuous operation in power plant boiler ducts, APH air preheaters, and DeNOx systems, featuring 1200°C CMS-Bio thermal bolster insulation.

How does FlueTec protect against abrasive particulate wear? +

Abrasion-resistant Hardox (≤250°C) or AISI 304/310S stainless steel internal flow liners and particulate deflection barriers (SAPB/DAPB) shield composite fabric layers from erosive clinker and ash.

What is the maximum operating temperature of FlueTec expansion joints? +

FlueTec series is designed for continuous duty from +100°C / +750°C (peak +800°C <30 min) in dry flue gas streams containing heavy abrasive particulate loads.

Which industrial facilities are ideal for FlueTec installations? +

Cement cyclone preheaters, tertiary air ducts, steel mill sinter plants, biomass boilers, and electrostatic precipitator (ESP) inlet/outlet connections.

Manufacturing & Engineering Standards

Strict compliance with internationally recognized engineering standards.

RAL-GZ 719

RAL-GZ 719 Technical Guidance →

Official RAL-GZ 719 (March 2017) governs single and multi-layer designs. Baseline tests cover EN 1593 Nekal® (≥50 hPa), DIN 53508, and ISO 13934-1.

FSA-DSJ

FSA Non-Metallic Ducting Guidelines →

The FSA Non-Metallic Handbook (Chapters 4 & 5) sets clamping and torque rules. It specifies R ≥ 3 mm radii and 10–12% belt slack.