FanTec™ Fabric Expansion Joints for Fan Suction Zones
CASE STUDY

FanTec™ Fabric Expansion Joints for Fan Suction Zones

Field Problem / Customer Requirement

A 4,500 tpd cement plant ran at -12,000 Pa suction vacuum. Heavy vibration hit its 2,600 × 1,800 mm ID fan duct. At +180°C continuous gas temperature, rigid rubber connectors cracked from cyclic fatigue.

BundleTec Innovation and Engineering Solution

BundleTec manufactured a multi-ply Silicone/EPDM-coated E-glass FanTec™ expansion joint for L_inst = 220 mm. An internal AISI 304 anti-flutter flow sleeve stabilizes suction turbulence and prevents vacuum draw-in.

Clamping bars feature R ≥ 3 mm bevelled inner edges per FSA Non-Metallic Handbook (Ch. 4–5). The flexible belt isolates 95% of structure-borne fan vibration, cutting bearing loads.

Each unit passed EN 1593 Nekal® (≥50 hPa) testing for ±15,000 Pa duty. The assembly logged over 34,000 operating hours.

Do you have a similar process problem?

Consult Our Lead Engineers Now →
Share:
BundleTec

Field Engineering Parameters & Verification Matrix

This FanTec™ joint was custom engineered at our plant for exact pressure, temperature, and duct movements. Before fabrication, multi-layer thermal drop and liner clearances were verified in FabricSim™.

Project Engineering & Field Verification Matrix
Engineering ParameterVerified Field Specification
Product SeriesFanTec™
Plant & Duct Location4,500 tpd Cement Plant · Induced-Draft (ID) Fan Suction Duct
Duct Cross-Section & L_inst2,600 × 1,800 mm (8,800 mm perimeter) · L_inst = 220 mm
Operating & Peak Temperature-15°C to +180°C Continuous (+200°C Peak)
Design Pressure & Gas Velocity-12,000 Pa (-120 mbar) Suction Vacuum / ±15,000 Pa Rated
Process MediumCement Kiln ID Fan Suction Flue Gas
Composite & Frame ArchitectureMulti-Ply Silicone/EPDM E-Glass Belt + AISI 304 Anti-Flutter Sleeve + R ≥ 3 mm Clamping Bars
Movement Envelope±25 mm Axial · ±15 mm Lateral · 95% Vibration Isolation
Verified Field Outcome>34,000 Operating Hours · Reduced Fan Bearing Vibration
Quality & Leak VerificationRAL-GZ 719 (EN 1593 Nekal® ≥50 hPa) + FSA Non-Metallic Handbook (Ch. 4–5)