Field Problem / Customer Requirement
A 420 MW CCGT plant needed a near-zero-emission gas-tight joint at its 4,200 × 2,800 mm HRSG inlet diffuser. Flue gas ran at +580°C continuous with +650°C fast-start peaks and 60 m/s turbulent flow. Legacy belts suffered bolster slumping, hot flanges, and exhaust bypass.
BundleTec Innovation and Engineering Solution
BundleTec engineered an 8-layer GtTec™ fabric expansion joint for the L_inst = 350 mm gap. A heavy slotted AISI 310S (1.4845) telescoping flow liner shields the belt from aerodynamic flutter.
Stepped 1200°C CMS-Bio bolsters and Inconel 625 wire-reinforced high-silica inner cloth cut radiant heat. This holds the virgin cross-laminated PTFE barrier below 260°C and outer skin below 60°C.
Each assembly passed EN 1593 Nekal® (≥50 hPa) soap-bubble testing plus optional helium QA before dispatch. Field logs confirm over 42,000 service hours with no bolster sag or detected exhaust leakage.
Do you have a similar process problem?
Consult Our Lead Engineers Now →Related Fabric Expansion Joint Series & FabricSim™ Simulation
For gas turbine exhaust and HRSG ducts facing +620°C to +1000°C thermal shock, explore our GtTec™ Series. Validate multi-layer thermal gradients and liner clearances in FabricSim™ Thermal Simulator.